3.3 ESE power power of the terminals must be received in the corresponding single-phase power on (see table diameter cable)with the double A core electric cable magnet's binding clamp and the ESE power source ten and a post connect, has nothing to do with the polarity. 3.3 the ESE power source's power source's binding clamps, must meet on the corresponding single-phase source (electric cable diameter see table)
制动器类型
|
制动器类型
|
|
5SE
450SE
|
Ф6六方孔平头螺钉
|
|
45SE
4SE
3SE
2SE
|
螺钉IIM20Xф130
30A/F
bolt
|
六方形ф24A/F
|
制动器类型
|
地脚螺栓孔
|
5SE
450SE
|
4-ф15
|
45SE
4SE
3SE
|
4-ф22
|
2SE
|
4-ф27
|
制动器类型
|
螺母9
nut
|
螺母10
nut
|
5SE
450SE
|
Ф24A/F
|
Ф24A/F
|
45SE
4SE
|
Ф30A/F
|
Ф30A/F
|
3SE
2SE
|
Ф27A/F
|
Ф30A/F
|
制动器类型
|
套管
|
5SE
450SE
|
Ф26.9×2.6-500
|
45SE
4SE
|
Ф38×4-1450
|
3SE
2SE
|
Ф54×5-1500
|
制动器类型
|
5SE
|
450SE
|
4SE
|
3SE
|
||
制动器数量
Brake quantity
|
1
|
2
|
1
|
1
|
1
|
|
输入
电压
|
220V
|
4
|
5
|
6.3
|
6.3
|
8
|
380V
|
2
|
3.15
|
4
|
4
|
4
|
|
每小时*大动作频率
|
1200
|
840
|
600
|
600
|
600
|
编号
|
名称
|
2.04
|
制动衬垫装置
|
5.08
|
线圈、铁、防雨尘罩等
|
2.12
|
补偿装置
|
6.32
|
连接环全套
|
故障
|
检查
|
检修
|
(1)制动器打不开
|
检查线圈电压标准电压
开闸电压:DC170V
维持电压:18V
|
检查电源输入电压,保险丝位置
*大电压降:10%
|
检查间隙,平均间隙:
3.5mm
|
无开闸电压,更换电源**极板
|
|
安装制动衬垫
|
||
(2)制动器不能保持松闸状态
|
检查维修电压,约18V
|
更换电源**极板
|
间隙堵塞,铁不能逐渐接触
|
清洁间隙,检查密封
|
|
(3)正确操作一段时间后,制动器不能打开
|
检查1,确保棘爪按钮状态良好
|
|
(4)当供能时制动盘过热
|
在松闸时,制动衬垫与制动盘之间间隙不足
|
调整制动衬垫
|
制动盘相对于底座的垂直度:&plu**n;4%
|
调整
|
联系人:牛京京(微信同号)